DONGGUAN CARNO MACHINERY CO., LTD.
Home> Products> Cooling Tower> Cooling water tower accessories
Cooling water tower accessories
Cooling water tower accessories
Cooling water tower accessories

Cooling water tower accessories

Payment Type:L/C,T/T

Incoterm:FOB,CFR,CIF,EXW,FCA,DDU,Express Delivery

Transportation:Ocean,Land,Air,Express

Port:Yantian Port, Shenzhen,Shekou Port, Shenzhen,Nansha Port, Guangzhou

Product Description
Product Attributes

BrandCarno

Supply Ability & Additional Information

PackagingExport enclosed wooden box

Productivity500.000bars/month

TransportationOcean,Land,Air,Express

Place of OriginGuangdong, China

Supply AbilityNormal

CertificateCE, SGS

HS Code8418692090

PortYantian Port, Shenzhen,Shekou Port, Shenzhen,Nansha Port, Guangzhou

Payment TypeL/C,T/T

IncotermFOB,CFR,CIF,EXW,FCA,DDU,Express Delivery

Packaging & Delivery
Selling Units:
Piece/Pieces
Package Type:
Export enclosed wooden box
Picture Example:
Water towers are facilities used to store water sources, commonly found in rural areas or areas without stable water supply systems. The water tower consists of many components that work together to ensure the safety and reliability of the stored water source. In this article, we will introduce some water tower accessories and their functions.
1. Water tower tank body: The water tower tank body is the main part of the water tower, used to store and protect water sources. It is usually made of steel or concrete and has sufficient strength to withstand the weight of water and external pressure. The tank body of a water tower usually has corrosion resistance and leak resistance characteristics to ensure the quality and safety of the water source.
2. Water pump: A water pump is an important device that lifts water sources from the ground or well to the tank body of a water tower. It transfers water by creating negative and positive pressures. A water pump usually consists of an electric motor, impeller, and sealing device, which can adjust the flow and pressure of water as needed. The normal operation of the water pump is crucial for the normal operation of the water tower.
3. Inlet pipeline: The inlet pipeline is used to introduce water sources into the water tower tank. The water inlet pipeline is usually located above the ground, and water is introduced into the tower body through a pipeline connected to the water source. To ensure water quality safety, filters and valves are usually installed in the inlet pipeline to remove impurities and regulate water flow.
4. Drainage pipeline: The drainage pipeline is used to remove water from the water tower and use it. It is usually located at the bottom of a water tower and connected through pipes to areas such as kitchens, bathrooms, or farmland that require water. In order to control the flow and pressure of water, drainage pipelines are usually equipped with valves and flow controllers.
5. Water level gauge: The water level gauge is used to measure the water level in the water tower. It is usually installed on the side of the water tower tank and detects changes in water level through floats or sensors. The water level gauge can provide accurate water level information, help users understand the water volume in the water tower, and take timely measures to replenish water sources.
6. Safety valve: The safety valve is used to release pressure when the pressure established in the water tower exceeds the safety limit. It controls pressure by automatically opening or closing to protect the safety of the water tower. Safety valves are usually used in conjunction with pressure gauges and alarms, and when the pressure is abnormal, an alarm is issued to remind users to carry out maintenance and repairs.
7. Water purifier: Water purifiers are used to filter and purify water sources, remove impurities and kill bacteria. Water purifiers are usually installed on the inlet pipeline or at the outlet of the water pump to ensure that the water source entering the water tower is safe and clean. It can choose different filtering materials and processes based on the quality and needs of the water source.
8. Water pump controller: The water pump controller is used to monitor and control the operation of the water pump. It can automatically start and stop the water pump based on the water level, pressure, and water demand in the water tower. The water pump controller can also detect faults and abnormalities in the water pump, and issue an alarm for timely repair and maintenance.
The above are some common water tower accessories and their functions. The selection and configuration of water tower accessories should be based on actual needs and conditions to ensure the safety and reliable supply of water sources. When using water tower accessories, regular inspections and maintenance should be carried out to extend their service life and ensure normal operation.

model discharge(m3/h) fan(cmm) base diameter (mm) height(mm) Fan diameter (mm) motor(KW) I inlet and outlet water(mm) drainage(mm) overflow (mm) moisturizing(mm) net weight (KG)  Operating weight(KG) DBA
8T 6.23 70 930 1460 550 0.18 40 25 25 15 42 180 52
10T 7.81 85 930 1640 650 0.18 40 25 25 15 46 190 52.5
15T 11.7 140 1170 1525 650 0.37 50 25 25 15 60 298 52.5
20T 15.62 160 1170 1690 770 0.56 50 25 25 15 80 320 52.5
25T 19.51 200 1400 1875 770 0.75 80 25 25 15 110 540 53
30T 23.4 230 1650 1845 770 0.75 80 25 25 15 135 550 53
40T 32.21 280 1650 1910 930 1.5 80 25 25 15 150 590 53
50T 39.24 330 1830 1940 930 1.5 80 25 25 15 210 1050 53
60T 46.8 420 2100 2080 1180 1.5 100 25 25 20 260 1280 53.5
80T 62.64 450 2100 2180 1180 1.5 100 25 25 20 290 1410 54
100T 78.12 700 2900 2345 1450 2.2 125 25 25 20 550 1650 54
125T 97.56 830 2900 2345 1450 2.2 125 25 25 20 550 1650 54
150T 117 950 2900 2525 1450 2.2 150 25 25 20 600 1750 55.5
175T 136.8 1150 3310 2870 1750 4 150 25 25 20 870 2000 55.5
200T 156.24 1250 3310 2870 1750 4 150 25 25 20 900 2100 56
225T 175.5 1500 4120 3640 2130 5.5 200 40 40 25 1100 2870 56
250T 195.12 1750 4120 3640 2130 5.5 200 40 40 25 1200 2950 57
300T 234 2000 4730 3650 2430 7.5 200 40 40 25 1820 4050 58
350T 273.24 2200 4730 3650 2430 7.5 200 40 40 25 1890 4100 59
400T 312.1 2400 5600 3870 2740 7.5 200 50 50 40 2920 5900 60
500T 372.4 2600 5600 3870 2740 7.5 250 50 50 40 3010 6000 60
600T 459 3750 6600 4900 3400 11 250 80 80 40 4050 9450 60.5
700T 547.2 4000 6600 4900 3400 11 250 80 80 40 4200 9650 61
800T 626.4 5000 7600 4950 3700 15 300 100 100 50 4900 12100 61.5
1000T 781.2 5500 7600 4950 3700 15 300 100 100 50 5100 12400 62
Hot Products
Home> Products> Cooling Tower> Cooling water tower accessories
Send Inquiry
*
*

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send